Users Online: 1714 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions | Subscribe | Contacts | Login 


RSACP wishes to inform that it shall be discontinuing the dispatch of print copy of JOACP to it's Life members. The print copy of JOACP will be posted only to those life members who send us a written confirmation for continuation of print copy.
Kindly email your affirmation for print copies to dranjugrewal@gmail.com preferably by 30th June 2019.

 
RESEARCH PAPER
Year : 2010  |  Volume : 26  |  Issue : 4  |  Page : 470-474

Effect of supplementing oxygen with positive end expiratory pressure during elective caesarean section under spinal anaesthesia on foetus


1 Associate Professor, Department of Anaesthesiology, Kasturba Medical College, Manipal, India
2 Resident, Department of Anaesthesiology, Kasturba Medical College, Manipal, India
3 Additional Professor, Department of Anaesthesiology, Kasturba Medical College, Manipal, India

Correspondence Address:
Ramesh Prabhu
Associate Professor, Department of Anaesthesiology, Kasturba Medical College, Manipal
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 21547172

Rights and PermissionsRights and Permissions

Background: It is known fact that pre-oxygenation with positive end-expiratory pressure (PEEP) improves the Partial pressure of oxygen (PO 2 ). In this regard not many studies have been done in pregnant women to know its effect on foetus. In this randomised double blind controlled study, we analysed effect of pre-oxygenation with PEEP during caesarean section on foetal umbilical venous PO2. Patients & Methods: 40 term pregnant women, ASA I or II, undergoing elective Caesarean section under spinal anaes­thesia were randomly divided into PEEP and Non-PEEP groups of 20 each. PEEP group received oxygen flow of 6 L/minute with PEEP of 5 cmH2 O using a modified Mapleson A circuit with fixed unidirectional PEEP valve at the expiratory port during pre-oxygenation and Non PEEP group received same fresh gas flow of oxygen using same breathing circuit without PEEP. Maternal arterial blood samples were collected before applying PEEP and at the end of 5 minutes of facemask application for oxygen analysis. Immediately after baby was delivered umbilical venous samples were taken for blood gas analysis. Results: Both groups were comparable in terms of maternal baseline oxygen saturation (Spo 2 ) and base line Po 2 . After 5 minutes PO 2 was higher in PEEP Group than non PEEP group (491.65 + 49.96 vs. 452.08 + 77.61). Umbilical venous Po 2 in PEEP group was higher than non PEEP group (34.22 + 6.50 vs. 28.29 + 6.10 mm of Hg). Conclusion: Application of PEEP during pre-oxygenation for spinal anaesthesia can increase foetal umbilical venous PO 2.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2749    
    Printed138    
    Emailed2    
    PDF Downloaded304    
    Comments [Add]    
    Cited by others 1    

Recommend this journal