Trachlight-guided intubation with esophageal combitube in situ


Department of Anaesthesia and ICU Government Medical College, Jammu, Jammu and Kashmir, India

Date of Web Publication4-Oct-2012

Correspondence Address:
Rajesh Mahajan
quarter no- c-3 medical college enclave, bakshi nagar, Jammu, Jammu and Kashmir
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9185.101963

Rights and Permissions

How to cite this article:
Mahajan R, Charak DS, Bassi R, Shafi F. Trachlight-guided intubation with esophageal combitube in situ. J Anaesthesiol Clin Pharmacol 2012;28:544-5

How to cite this URL:
Mahajan R, Charak DS, Bassi R, Shafi F. Trachlight-guided intubation with esophageal combitube in situ. J Anaesthesiol Clin Pharmacol [serial online] 2012 [cited 2019 May 20];28:544-5. Available from: http://www.joacp.org/text.asp?2012/28/4/544/101963

Sir,

The esophageal tracheal combitube (ETC) (Tyco Kendall Co., Mansfield, MA) is a supralaryngeal airway device recommended for difficult airway management. [1] We describe airway management in a patient with difficult airway using combitube and Trachlight™ (Laerdal Medical Inc., Armonk, NY).

A 48-year-old man presented to the emergency department with head injury following a road traffic accident. Patient was unconscious and was graded as Glasgow Coma Scale (GCS) 7. He had fracture of nasal bones with epistaxis. He was tachypneic and crepts and wheeze were heard on chest auscultation. Patient's lungs were preoxygenated with 100% oxygen, manual inline stabilization was applied, and rapid sequence induction was carried while applying cricoid pressure. Laryngoscopy revealed a grade-4 Cormack-Lehane view, which did not improved on releasing the cricoid pressure and backward, upward, and rightward pressure maneuver. After two attempts at direct laryngoscopy and bougie assistance, patient began to desaturate. A size ETC 37Fr SA was successfully placed with the distal tip in the esophagus. The lungs could be successfully ventilated via the blue pharyngeal lumen, as evident by capnography, bilateral auscultation of the chest and improvement in oxygen saturation to 97%. Computerized tomography scan of the patient's head and neck revealed bilateral multiple contusions with midline shift and fracture of right frontal bone. Cervical spine was normal. As elective ventilation was indicated, exchange of ETC to an endotracheal tube was needed. Direct laryngoscopic examination, after partial deflation of the oropharyngeal balloon, revealed Cormack-Lehane grade-4 view. Two attempts to intubate trachea using a gum elastic bougie failed. A fiberoptic bronchoscope was passed alongside the ETC after partial deflation of the cuff, but we failed to negotiate it into the glottic aperture as the vision was poor due to bleeding in the oral cavity.

It was decided to attempt light wand aided tracheal intubation. An adult light wand was threaded through the Murphy eye of size 8-mm ID endotracheal tube [Figure 1]. [2] The cuff of the ETC was partially deflated and the Trachlight wand (Laerdal Medical, Armonk, NY, USA) was passed via oral cavity alongside the ETC. Gentle maneuvering of the Trachlight wand led to its entry into the trachea as evident by well-circumscribed glow in the anterior neck slightly below the thyroid prominence. The tracheal tube was advanced over the wand. A resistance was felt to the passage of the tracheal tube into the glottic aperture, which was overcome by anticlockwise rotation by 90΀, which facilitated its passage into the trachea. Light wand was removed and the position was confirmed by bilateral auscultation of chest and capnography. ETC was also removed and elective ventilation continued. Patient was weaned from ventilator after 12 days with a GCS of 11.
Figure 1: Tracheal tube mounted on the Trachlight for intubation

Click here to view


The ETC has been used as a rescue device for emergency airway management. ETC can be exchanged for conventional endotracheal tube using various techniques including direct and video laryngoscopy, fiberoptic-assisted intubation, and surgical airway. [3],[4] However, exchanging the ETC for definitive airway may not be straightforward. [4] Its insertion in precarious circumstances, such as after multiple attempts after failed ventilation/intubations and esophageal/tracheal distortion by the ETC rendering visualization of the glottic aperture, may make tracheal intubation difficult. [4],[5] Leaving the ETC in place while manipulating the airway confers a safety margin to continue ventilation and oxygenation. Fiberoptic intubation after partial deflation of the oropharyngeal balloon of the ETC is feasible, [3] but this failed in our case due to obscuring of the airway by blood. Light wand intubation does not require direct viewing of the glottic aperture. Light wand guided intubation is useful in situations in which flexible endoscopy is difficult, as in cases where the airway is obscured by secretions or blood or when patient's head cannot be manipulated. [4] We found Trachlight to be very useful tool for exchanging ETC with an endotracheal tube.

 
  References Top

1.Frova G, Sorbello M. Algorithms for difficult airway management: A review. Minerva Anestesiol 2009;75:201-9.  Back to cited text no. 1
[PUBMED]    
2.Biehl JW, Bourke DL. Use of the lighted stylet to aid direct laryngoscopy. Anesthesiology 1997;86:1012.  Back to cited text no. 2
[PUBMED]    
3.Gaitini LA, Vaida SJ, Somri M, Fradis M, Ben-David B. Fiberoptic-guided airway exchange of the esophageal-tracheal Combitube in spontaneously breathing versus mechanically ventilated patients. Anesth Analg 1999;88:193-6.  Back to cited text no. 3
[PUBMED]    
4.Dorsch JA, Dorsch SE. Devices for managing difficult airway. In: Dorsch JA, Dorsch SE, editors. Understanding anesthesia equipment. 5 th ed. Philadelphia USA: Lippincott Williams and Wilkins; 2008. p. 61-684.  Back to cited text no. 4
    
5.Portereiko JV, Perez MM, Hojman H, Frankel HL, Rabinovici R. Acute upper airway obstruction by an over-inflated Combitube esophageal Obturator balloon. J Trauma 2006;60:426-7.  Back to cited text no. 5
[PUBMED]    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
   References
   Article Figures

 Article Access Statistics
    Viewed1094    
    Printed46    
    Emailed0    
    PDF Downloaded273    
    Comments [Add]    

Recommend this journal