ProSeal TM laryngeal mask airway cuff pressure changes with and without use of nitrous oxide during laparoscopic surgery


Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, Old Rajinder Nagar, New Delhi, India

Correspondence Address:
Bimla Sharma
Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, Old Rajinder Nagar, New Delhi - 110 060
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9185.105795

Rights and Permissions

Background: The ProSeal TM laryngeal mask (PLMA) is increasingly being used as an airway device for laparoscopic surgery. Its silicone cuff allows diffusion of nitrous oxide, carbon dioxide and other gases with resultant rise in its intracuff pressure during anesthesia. The present study was designed to investigate the intracuff pressure changes during anesthesia with and without nitrous oxide in patients undergoing laparoscopic surgery lasting up to two hours. Materials and Methods: One hundred patients, American Society of Anesthesiologists physical status 2 and 3, undergoing general anesthesia with muscle paralysis, were randomized into two groups of 50 patients each to receive an anesthetic gas mixture containing either oxygen and nitrous oxide (group N) or oxygen and air (group A). Following insertion of an appropriate size PLMA, its cuff was inflated with air to an intracuff pressure of 45 mm Hg. The cuff pressure was measured every 10 minutes for the entire course of anesthesia. The position of the device was also assessed fiberoptically and postoperative airway complications were recorded. Results: The maximum intracuff pressure recorded in group N was 103 ± 4.7 mm Hg vs. 45.5 ± 1.5 mm Hg in group A. The percentage rise in cuff pressure every 10 minutes was also highly significant ( P < 0.001) being maximum in first 10 min in group N. The incidence of postoperative airway complications was comparable between the two groups. Conclusion: The results of this study demonstrate that the intracuff pressure of the PLMA increases progressively over time when the breathing gas mixture contains nitrous oxide.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3134    
    Printed93    
    Emailed1    
    PDF Downloaded479    
    Comments [Add]    
    Cited by others 4    

Recommend this journal