Waxing and waning tracheal tube obstruction: A diagnostic dilemma!


1 Department of Anaesthesia and Critical Care, Deendayal Upadhyay Hospital, New Delhi, India
2 Department of Anaesthesia and Intensive Care, Vardhman Mahavir Medical College and Safdarjang Hospital, New Delhi, India

Date of Web Publication1-Oct-2013

Correspondence Address:
Parul Mullick
Department of Anaesthesia and Intensive Care, Vardhman Mahavir Medical College and Safdarjang Hospital, New Delhi 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9185.119132

Rights and Permissions

How to cite this article:
Kumar A, Mullick P. Waxing and waning tracheal tube obstruction: A diagnostic dilemma! . J Anaesthesiol Clin Pharmacol 2013;29:562-3

How to cite this URL:
Kumar A, Mullick P. Waxing and waning tracheal tube obstruction: A diagnostic dilemma! . J Anaesthesiol Clin Pharmacol [serial online] 2013 [cited 2019 Apr 20];29:562-3. Available from: http://www.joacp.org/text.asp?2013/29/4/562/119132

Sir,

A 26-year-old victim of road traffic accident was brought to the emergency department in an unconscious state with nasal bleeding. His airway was secured immediately using size 8, oral cuffed PVC endotracheal tube (ETT). He was posted for subdural hematoma drainage two hours later. General anesthesia was administered using standard technique after confirming ETT position and patency, and the patient was positioned (anti-Trendelenburg). After 15 min, airway pressure (Paw) increased from 19 to 28 cm H 2 O, EtCO 2 increased from 32 to 51 mmHg, and SpO 2 was 98%. Auscultation revealed bilateral reduced air entry and wheeze. Bronchospasm due to inward migration of ETT with carinal impingement following surgical positioning was considered. ETT position was reconfirmed and kinking was excluded. Bronchodilators (salbutamol and combination of levosalbutamol with ipratropium bromide inhaler puffs, theophylline injection) and hydrocortisone intravenous (IV) was administered. A lubricated suction catheter was advanced through the ETT and a small quantity of blood-tinged secretion was suctioned. The Paw decreased to 23 cm H 2 O, EtCO 2 to 42 mmHg, and the reservoir bag compliance improved. Waxing and waning of airway resistance occurred several times. Finally, there was a marked increase in Paw 38 cm H 2 O, the reservoir bag felt stony hard, and it was impossible to ventilate even after changing the anesthesia circuit. The suction catheter could not be advanced through the ETT. Cuff deflation resulted in no improvement in ventilation excluding cuff herniation. We could not visualize the ETT lumen using a fiberoptic bronchoscope, as it was not available in the emergency operation theatre. Suspecting ETT obstruction, we replaced it with a new one, following which we could ventilate our patient. The removed ETT had an impacted blood clot covering the tube tip and Murphy's eye [Figure 1]. After completion of surgery, the patient was shifted to the ICU for further management.
Figure 1: Blood clot covering the endotracheal tube tip and Murphy's eye

Click here to view


Xue et al., reported three cases of ETT obstruction caused by blood clot. [1] They speculated that local tracheal injury following traumatic intubation, cuff over inflation, or tube movement during changes in head position could result in bleeding and clot formation. [1] Endotracheal intubation has the potential to cause tracheal trauma and subsequent clot formation. [2] Our patient had a history of nasal bleeding. It is plausible that he either aspirated blood or sustained tracheal injury during intubation, leading to local bleeding and pooling of blood in the dependent part of the ETT in supine position and clot formation. Surgical positioning and positive pressure ventilation led to distal clot migration and obstruction. Catheter advancement probably created a new channel for air passage through the clot or between the clot and ETT, improving ventilation. The waxing and waning of airway resistance occurred due to distal displacement and movement of clot in its vertical axis, leading to opening and closing of air channels. Later, the clot migrated and got impacted, completely blocking both the tip and Murphy's eye of the ETT impeding ventilation.

Previous reports of blood clot-induced ETT obstruction describe inability to advance a catheter through the ETT. [1],[3] In our case, the catheter could be negotiated through ETT initially because of partial block. Therefore, while inability to advance a catheter beyond the tube tip may indicate intraluminal obstruction, the ability to advance it does not exclude obstruction, especially when the obstruction is partial. It may be prudent to use a fiberoptic bronchoscope as a diagnostic aid for early assessment of an adverse respiratory event in an intubated patient.

 
  References Top

1.Xue FS, He N, Luo MP, Liao X, Zhang YM. Endotracheal tube obstruction by unexpected blood clot in anesthetized children: A report of three cases. Paediatr Anaesth 2009;19:545-7.  Back to cited text no. 1
    
2.Pazanin L, Misak VB, Goreta N, Marekoviæ Z, Petrovecki V. Iatrogenic tracheal laceration causing asphyxia. J Forensic Sci 2008;53:1185-7.  Back to cited text no. 2
    
3.Park C, Kim H, Yum K. Acute obstruction of an endotracheal tube: A case report. Anesth Prog 2004;51:62-4.  Back to cited text no. 3
    


    Figures

  [Figure 1]


This article has been cited by
1 Endotracheal Tube Obstruction Due to Aspirated Foreign Bodies
Ahmad A. Alwassia,Arun Jose,Leen Raddaoui,Katrina Hawkins,Jalil Ahari
Clinical Pulmonary Medicine. 2018; 25(1): 20
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
   References
   Article Figures

 Article Access Statistics
    Viewed945    
    Printed18    
    Emailed0    
    PDF Downloaded211    
    Comments [Add]    
    Cited by others 1    

Recommend this journal