Users Online: 264 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions | Subscribe | Contacts | Login 


RSACP wishes to inform that it shall be discontinuing the dispatch of print copy of JOACP to it's Life members. The print copy of JOACP will be posted only to those life members who send us a written confirmation for continuation of print copy.
Kindly email your affirmation for print copies to dranjugrewal@gmail.com preferably by 30th June 2019.

 
ORIGINAL ARTICLE
Year : 2015  |  Volume : 31  |  Issue : 3  |  Page : 324-328

Propofol requirement for insertion of I-gel versus laryngeal mask airway: A comparative dose finding study using Dixon's up-and-down method


Department of Anaesthesiology, Lokmanya Tilak Municipal Medical College and General Hospital, Mumbai, Maharashtra, India

Correspondence Address:
Aparna Ashay Nerurkar
D-104, Presidential Towers, LBS Road, Ghatkopar (W), Mumbai - 400 086, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9185.161666

Rights and Permissions

Background and Aims: Propofol is the drug of choice when used as sole anesthetic agent for placement of supraglottic airway devices. We aimed to find and compare the propofol dose required for smooth first attempt insertion of I-gel versus the classic laryngeal mask airway (cLMA) using Dixon's up-and-down method. Material and Methods: Prospective randomized controlled trial (n-60) was planned. I-gel or cLMA was inserted 60 s after propofol injection whose dose was calculated based on previous patients response as per Dixon's up-and-down method. Propofol requirements for successful placement of devices was noted and compared. Difference between the groups was measured by ANOVA. A P < 0.05 was considered as statistically significant. Results: Significantly lower (P < 0.001) propofol dose was required for I-gel (2.02 ± 0.26 mg/kg) insertion than cLMA (2.70 ± 0.28 mg/kg). Conclusions: I-gel requires significantly lower dose of propofol for insertion when compared to cLMA.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2206    
    Printed39    
    Emailed1    
    PDF Downloaded449    
    Comments [Add]    
    Cited by others 2    

Recommend this journal