REVIEW ARTICLE
Year : 2015  |  Volume : 31  |  Issue : 4  |  Page : 440-449

Small is the new big: An overview of newer supraglottic airways for children


Department of Anesthesia and Critical Care, Armed Forces Medical College, Pune, Maharashtra, India

Date of Web Publication5-Nov-2015

Correspondence Address:
Rakhee Goyal
NP-5 MH, CTC, Pune - 410 040, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9185.169048

Rights and Permissions
  Abstract 

Almost all supraglottic airways (SGAs) are now available in pediatric sizes. The availability of these smaller sizes, especially in the last five years has brought a marked change in the whole approach to airway management in children. SGAs are now used for laparoscopic surgeries, head and neck surgeries, remote anesthesia; and for ventilation during resuscitation. A large number of reports have described the use of SGAs in difficult airway situations, either as a primary or a rescue airway. Despite this expanded usage, there remains little evidence to support its usage in prolonged surgeries and in the intensive care unit. This article presents an overview of the current options available, suitability of one over the other and reviews the published data relating to each device. In this review, the author also addresses some of the general concerns regarding the use of SGAs and explores newer roles of their use in children.

Keywords: Air Q, Ambu Aura, i-gel, laryngeal mask airway, laryngeal tube suction, pediatric, pediatric airway management, 2 nd generation device, supraglottic airways


How to cite this article:
Goyal R. Small is the new big: An overview of newer supraglottic airways for children . J Anaesthesiol Clin Pharmacol 2015;31:440-9

How to cite this URL:
Goyal R. Small is the new big: An overview of newer supraglottic airways for children . J Anaesthesiol Clin Pharmacol [serial online] 2015 [cited 2020 Aug 15];31:440-9. Available from: http://www.joacp.org/text.asp?2015/31/4/440/169048


  Introduction Top


Since the last review in 2009 by White et al. and Ramesh and Jayanthi in 2011, [1],[2] many advanced supraglottic airway (SGA) devices are now available in smaller sizes thereby expanding their usability and reliability for pediatric airway control. It is not that the older devices did not perform well, but the newer ones come with added features that have increased the options for their use for specific indications. This review addresses some of the general concerns about SGAs in children and briefly describes the newer devices and their role in specific clinical scenarios.


  Evolution of Supraglottic Airways Top


Everything is difficult before it becomes easy

The SGA saga began in East End of London in 1981 when Dr. Archie Brain felt the need for an effective airway that could be inserted easily, rapidly, without any trauma when used even by the unskilled. After several years of material and design modification, the laryngeal mask airway (LMA) was created and marketed in late 1987. The first reports on the pediatric classic LMA (cLMA) came in the early nineties. The flexible and ProSeal LMA came later, along with additional features. Meanwhile, from 2003 onwards when the patent for cLMA expired, other manufacturers (Portex Soft seal, Cobra PLA, Ambu Aura) started marketing similar pediatric devices with some design modifications, both in reusable and disposable forms. Most of the other advanced models were launched after 2009 such as LMA Supreme and i-gel, with a gastric drain port; and Air Q and Ambu Aura i, the first intubating airway devices in pediatric sizes. [Table 1] shows some of the characteristics of the SGAs available in pediatric sizes. The core issues of the supraglottic approach to the airway that the newer designs have targeted to address are gastric insufflation, airway protection, effective ventilation and securing definitive airway in difficult scenarios.
Table 1: Pediatric supraglottic airways-characteristics and special features

Click here to view



  The Anatomy Top


The airway is funnel shaped in children, widest at the supraglottic level and narrowest at the subglottic compared to the uniformly cylindrical larynx in adults. [3] The supraglottic area appears to be proportionately as wide as in adults and, therefore, the pediatric SGAs function well as a scaled down version of the adult. However, the evidence in adults should not be extrapolated to infants and smaller children because of the difference in their respiratory physiology (low functional residual capacity and, therefore, low tolerance to hypoxia). Besides, the epiglottis is large and floppy in smaller children and can partially obstruct the glottic view due to its down folding during insertion of the device. Various techniques have been described in the literature to overcome this obstruction such as insertion with inflated or partially inflated cuff, insertion with 90΀ or 180΀ rotation, to name a few. Some of the devices have a specially designed reinforced cuff tip to prevent epiglottic down folding (Vital seal, Anandic Medical System, Feuerthalen, Switzerland and Ambu Aura, Ballerup, Denmark).


  General Considerations Top


Reusable versus disposable supraglottic airway

Most SGAs are available in reusable (40-50 times use) as well as disposable forms. Reusable SGAs have been commonly used across the globe in the past because of their easy availability and possibly, reduced cost per patient but they have also been implicated as likely vectors for transmission of prion disease, e.g., Creutzfeldt-Jakob disease. Prions are infective proteins that are present in higher concentration in the tonsillar tissue and are likely to adhere to a SGA during use (more with local mucosal trauma). Studies have shown that these proteins are resistant to conventional cleaning and autoclaving. [4],[5] Coetzee reported that though no method completely eliminates protein contamination, ultrasonic cleaning was more effective than manual cleaning. [6] Richards et al. recommended that all devices be cleaned in isolation because protein cross-contamination occurs mainly during batch cleaning. [7] Though the author could not find any case of prion disease transmission with the use of SGA in literature (cases reported with neurosurgery and corneal surgery, not related to SGA), [8] some guidelines suggest that only disposable devices be used for tonsillectomies where the transmission risk is very high. [9] The author recommends the use of disposable devices for all suspected or diagnosed cases of prion disease and suggests that they be preferred over reusable devices for other routine cases also.


  Cuff Pressure Top


When the supraglottic cuff pressure is more than the mucosal perfusion pressure, it is likely to either cause postoperative pharyngolaryngeal symptoms like sore throat (dysphagia, dysphonia) or cause local mucosal trauma and nerve injuries. [10] SGAs with inflatable cuffs are prone for over inflation and may create pressures higher than 60 cm H 2 O, with maximum recommended volume of inflation typically with nitrous oxide that readily diffuses into the cuff. [11] Some of the newer devices like Air Q have recommended lower inflation volumes.

In 2010, Hockings et al. studied LMA size 1.5-3 with three different cuff pressures (20, cm 40 cm and 60 cm H 2 O) and found the lowest leak volume at a cuff pressure of 40 cm H 2 O and the highest at 60 cm H 2 O in all sizes. [12] Other studies (Ong et al., Licina et al.) have also demonstrated that clinical endpoints do not correctly estimate cuff pressures and higher pressures do not provide either better seal or lower leak, and on the contrary are liable to cause more morbidity. [13],[14] It, therefore, seems prudent to routinely monitor cuff pressure with a manometer. If it is not feasible in routine clinical practice, the author recommends the SGAs be inserted with the packaged volume of air in the cuff (that may be enough in many cases) [15] or cuffs to be inflated with the minimal volume of air that creates the best seal and provides adequate ventilation; caution must be exercised during their prolonged use.


  Oro-pharyngeal Seal Pressure Top


The crux of ventilation (especially positive pressure ventilation) is an effective seal of the glottis. A good seal facilitates good ventilation, as well as maintenance of the desired depth of anesthesia at lower fresh gas flows (without polluting the environment with the leaked gases). Lesser leaks into the esophagus prevent rise of intragastric pressure and thereby reduce the risk of regurgitation. However, the arithmetic of a good seal that assures complete airway protection has not been worked out. Theoretically, it may be agreed upon that it should be more than the ventilating airway pressure, but there is limited evidence to support a complete protection of the airway from blood and secretions (more so in oral/nasal surgeries). The author also recommends the oropharyngeal seal pressure (OSP) to be assessed routinely and also rechecked with every change of patient position. At this juncture, it is further clarified that a SGA is indicated only for fasting patients, thereby not meant to completely protect the airway from the gastric contents in spite of a good glottic seal.


  Fiberoptic View Through a Supraglottic Device Top


Most studies have attempted to correlate the fiberoptic bronchoscope (FOB) view through the SGA with ease of ventilation and intubation. A clear view of the glottis using the FOB has been correlated with adequate ventilation and easy endotracheal intubation via the SGA conduit. However, the FOB scoring has now been challenged as a dependable tool for SGA positioning. [16] Loke et al. found epiglottic impingement in 60% cases in size 2 cLMA, 58% in size 2.5 (n = 67) but all the children could be adequately ventilated. [17] Von Ungern-Sternberg et al. also demonstrated good ventilation despite poor FOB view (55% in smaller and 75% in larger cLMA). [18] It thus appears that a full glottic view may be neither achieved nor always necessary for primary ventilation. However, the blind passage of an endotracheal tube (ETT) is not recommended in view of possible trauma.

Overall, it would be prudent to appreciate the subtle interplay between glottic seal (or leaks around the cuff), cuff pressure (or inflation volume) and anatomic positioning of the device (or FOB view). Therefore, an optimal seal and cuff pressure should be maintained for all cases and a good FOB view would be preferred for the intubating devices.


  The Cost Factor Top


The factors that affect the overall cost are the cost of the SGA (disposable or reusable, 1 st or 2 nd generation type) and the infrastructure, time and staff required to re-sterilize the reusable devices. However, there is currently no data available on the use of SGA based on cost issues.


  Overview of Supraglottic Airways Currently Available in Pediatric Sizes Top


The cLMA has been the benchmark SGA for many years but since 2003, after the expiry of its patent, there have been many other 1 st generation devices available in small sizes, some with additional features for better performance. [19],[20] Vital seal and Ambu Aura have reinforced cuff-tip; the cuff of Portex® Soft Seal® (Smiths Medical, Kent, UK) has lesser permeability to nitrous oxide; and Ambu AuraOnce has a preformed shaft in order to facilitate easy insertion.

Flexible LMA, the first modification of the cLMA was specially designed for head and neck surgeries with a longer and narrower reinforced airway tube that could be folded and taped on the chin. It is now marketed as a reusable device, LMA Flexible™ (disposable version also available) and as single use in all sizes as Ambu AuraFlex, Laryseal Flex and AES Ultra Flex cuff pilot valve (CPV).

Cobra perilaryngeal airway (CobraPLA, Engineered Medical System, Indianapolis, IN, USA; 2003) is a single use 1 st generation device with similar ventilator efficacy vis-a-vis cLMA (Szmuk n = 200; Gaitini n = 80 higher OSP) though some studies have raised a few concerns regarding its safety (Polaner: Epiglottic folding in 77% infants; Passariello: Gastric insufflation in 21% children; Sunder: Device instability requiring frequent head adjustments in eye surgery). [21],[22],[23],[24],[25] With better and more reliable SGAs available for children, the CobraPLA is not particularly recommended for routine use.

ProSeal LMA (reusable with gastric drain port, bite block and a patented introducer as shown in [Figure 1]) has been used for spontaneous/controlled ventilation, laparoscopies, neonatal and pediatric resuscitation and as a conduit for tracheal intubation in children since 2005. [26],[27] It was the first 2 nd generation SGA with a drain port that allows passage of a drain tube through the esophagus up to the stomach for emptying fluids/gases so that the intra-gastric volume and pressure are low and the incidence of regurgitation is reduced. The ProSeal LMA has been the most reliable and thus most preferred SGA in children. [1]
Figure 1: Second-generation supraglottic devices (ProSeal laryngeal mask airway [LMA], i-gel, LMA Supreme)

Click here to view


Laryngeal mask airway Supreme is similar to ProSeal LMA except that it is single use and has a preformed shaft that obviates the need for an introducer [Figure 2]. Various studies have shown good airway characteristics with LMA Supreme in children. [28],[29],[30],[31],[32] Jagannathan et al. found it comparable with the ProSeal LMA and Francksen et al. with the i-gel and recommended it as an useful alternative to ProSeal LMA. [33],[34] However, besides personal preference, disposability and cost, there is no other obvious advantage of Supreme over the other 2 nd generation SGAs in children.
Figure 2: Laryngeal mask airway Supreme

Click here to view


Laryngeal tube (LT, VBM, Medizintechnik, GmbH, Germany; size 0-2.5) and its advanced version LT suction (LTS II; size 1-2.5) are SGAs with two cuffs (oropharyngeal and esophageal) with ventilation holes in between and an additional suction port in LTS II [Figure 3]. Though initial reports by Richebé et al. suggested reliable ventilation with LT only in children >10 kg, Schalk et al. found LT II a good alternative airway for children (n = 12, age 2-6 year) in difficult scenarios when endotracheal intubation and other SGAs had failed. [35],[36] Gaitini et al. compared LTS II with the ProSeal LMA and found it equally effective with higher OSP during spontaneous ventilation in children. [37] Though currently there is limited research on the efficacy and safety of LT for routine elective use in children, it promises to be a good tool in the difficult or emergency airway cart.
Figure 3: Laryngeal tube suction with color coded syringe to fill the cuffs

Click here to view



  Air Q Masked Laryngeal Airway Top


For many years, there were no intubating laryngeal masks available for children <30 kg. In 2009, Air Q (Cookgas LLC, Mercury Medical, Clearwater, Florida, USA) launched the first intubating masked laryngeal airway in size 1 and 1.5 (also size 0.5 for <4 kg weight neonate, later in 2012) for small children [Figure 4]a and b]. The shaft is broader, shorter and slightly curved with an elliptical cross-section (room for pilot balloon of ETT) and the color-coded 15 mm connector can be removed (but tethered to the shaft to avoid misplacement) for placement of a larger ETT. The elevation ramp and the keyhole shaped airway outlet help to direct the ETT toward the laryngeal inlet. The recommended volume of inflation and intracuff pressure (<60 cm H 2 O, ideal 20-30 cm H 2 O) are lesser than other devices of the same sizes. Endotracheal intubation via Air Q can be FOB guided or with an optical stylet. A patented tapered adapter that has ridges and grooves for firm fitting into the ETT can be used for removal of the device after intubation. In a recently published study, Whyte et al. studied 110 children of different ages using Air Q size 1-2.5 as a primary airway in five different head positions and found adequate ventilation in 108/110, good FOB view in 102/110, and an increase in OSP in flexion and decrease in head extension position. [38] There was blood staining on removal in 5%. Jagannathan et al. showed 100% success of tracheal intubation via Air Q (FOB, optical stylet, blind technique) during a retrospective audit over 1-year in 34 children with difficult airway. [39]
Figure 4: Air Q intubating reusable (a) and disposable (b); Air Q self pressurized (c) with permission from Mercury Medical, Clearwater, Florida for using the images

Click here to view


There is no pilot balloon for mask inflation in Air Q self-pressurizing (SP) masked laryngeal airway [Figure 4]c. An aperture between the airway tube and the cuff creates an open space with the incoming airflow that allows cuff inflation and pressure regulation, thereby avoiding the overinflation issues. Jagannathan et al. compared Air Q SP with LMA Unique (single use cLMA) in 60 children using size 2-2.5 and found good airway quality in both groups. [40] There was dysphonia (1/30) and dysphagia (4/30) in five cases of LMA Unique only (with cuff pressure 58-73 cm H 2 O). The authors have suggested Air Q SP as an effective alternative device where routine cuff pressure monitoring is not done.

Air Q blocker is the latest version but presently available only till size 2.5 for children weighing >30 kg. It has a drain tube through which a suction tube is passed. There is an inflatable cuff at the end of this tube. On inflation, the cuff seals the esophageal opening into the stomach, preventing any regurgitation of stomach contents.


  Ambu Aura Top


The Ambu Aura (Ambu A/S, Ballerup, Denmark) family of SGA has a variety of types like AuraOnce (single use, preformed shaft as shown in [Figure 5]), Aura 40 (preformed shaft, reusable), AuraStraight (straight shaft), AuraFlex (flexible shaft) and Aura i (intubating device as shown in [Figure 6]). There is no suction port in any model, and all are single use devices except Ambu 40. Ambu also manufactures a cuff pressure gauge, which has two "green" zones that indicate separate safe cuff pressure range for SGA and ETT. Overall, these devices have been shown to perform as well as their equivalents by other manufacturers without any obvious advantage over them.
Figure 5: Ambu AuraOnce

Click here to view
Figure 6: Ambu Aura i

Click here to view


Theiler et al. compared Ambu AuraOnce with i-gel in 208 children aged 1-17 years and found good overall performance with high OSP and success rate for both the devices. [41] When Jagannathan et al. compared the two intubating SGAs, Ambu Aura i and Air Q he found them to be equally effective in children except that size 1.5 of Aura i had limited space for a cuffed ETT. [42]

I-gel, a single use 2 nd generation SGA with a non-inflatable cuff has been available in small sizes since 2010 [Figure 1]. The epiglottic rest and side rims prevent downfolding of epiglottis, and the gastric port allows a 10-12 Fr suction catheter (absent in size 1). Easy insertion and high OSP has been reported with pediatric i-gel (Goyal 26; Fukuhara 22; Mitra 27 cm H 2 O), and there are no issues of overinflation because of the non-inflatable cuff. [43],[44],[45] Insertion of i-gel in the prone position as a rescue airway has also been reported in children. Overall, the author recommends i-gel as an effective 2 nd generation device for children but suggests that it must be secured with a tape after insertion to prevent displacement.

Streamlined Liner of the Pharyngeal Airway (Hudson, RCI) has a boot-shaped plastic body and a non-inflatable cuff, but there is no remarkable evidence in the last decade that supports its routine use in children.

The recently launched AES Ultra CPV (AES Inc., Black Diamond, WA, USA) promises to change the art of manually assessing the cuff pressure to a science of objective endpoint by incorporating a pressure indicator in the pilot balloon. It has three color zones that guide the user to inflate/deflate the cuff in order to maintain optimal pressure limits. It is single use (silicone/PVC/reinforced silicone), magnetic resonance imaging (MRI) compatible and manufactured in all sizes. Currently, there is no published study for AES ultra in children.


  Specific Scenarios Top


Laparoscopic surgeries pose unique challenges due to concerns of pneumoperitoneum, Trendelenburg position and low functional residual capacity in children. Ozdamar et al. used cLMA (n = 40) after inserting a nasogastric tube postinduction and did not have any case with pulmonary aspiration. [46],[47] Sinha et al. used ProSeal LMA in 30 children 6-month-8 year and found a comparable ventilation efficacy (OSP 29 cm H 2 O) with ETT (n = 30) without any major complication. [48] Mironov et al. also used LMA for 127 children undergoing short laparoscopic surgery and found stable hemodynamics, adequate ventilation and shorter awakening time compared to ETT. [49]

Though the present evidence of the safe use of SGA for laparoscopic surgeries is still limited, the 2 nd generation devices (ProSeal LMA, LMA Supreme and i-gel) should be (at least theoretically) better suited to provide adequate ventilation with greater safety (against gastric insufflation and regurgitation).


  Gastrointestinal Endoscopy Top


Upper gastrointestinal endoscopy requires deep sedation in children and an SGA can be used for assisting ventilation (without using a neuromuscular blocking agent). Fuentes-García et al. used cLMA and found similar efficacy with ETT except one failure. [50] Lopez-Gil et al. found ProSeal LMA insertion quicker with fewer airway complications compared with nasal prongs. [51] The pediatric endoscope can also be inserted through the drain port of a 2 nd generation SGA making it possible to ventilate and operate at the same time. The gastro-LT is a modification of the LT with a dedicated channel for endoscope, but there is no literature on its availability or use in children.


  Fiberoptic Bronchoscopy Top


Supraglottic airway can be used to administer oxygenation as well as provide a conduit for FOB in children. [52] Baker et al. used cLMA, Ambu AuraOnce, Portex Soft Seal, Boss Systems disposable silicone laryngeal mask and LMA Unique for flexible bronchoscopy in 100 children and felt lesser resistance with silicone (cLMA and Boss Systems) compared to PVC cuff during endoscope manipulation. [53]


  Remote Locations Top


When LMA is used during MRI, the ferrous content in the pilot valve interferes with the MRI findings, and this may sometimes lead to a misdiagnosis. [54] An in-vitro study of six SGAs (Classic, Unique, ProSeal, Supreme, Ambu AuraOnce, i-gel) showed artifacts in all except two devices Ambu and i-gel (no ferrous content) suggesting their suitability for MRI. [55],[56] The other available MRI compatible devices are AES Ultra, Solus™ LMA (Intersurgical, Berkshire, UK) and Laryseal™ MRI (Flexicare Medical Ltd., MG, UK).

Supraglottic airways have been effectively used for children undergoing other radiological and radiotherapy. [57],[58]


  Adenotonsillectomy Top


Although ETT is the gold standard, there is now good evidence that LMA can be used effectively and safely for adenotonsillectomies. [59],[60] Airway soiling with blood and obstruction due to mouth gag, leading to conversion to ETT were some of the concerns raised against the LMA, but most studies have proved this otherwise. John et al. used methylene blue dye in 64 patients to demonstrate LMA as an effective barrier to airway soiling. [61] Other investigators also found lesser incidence of aspiration with LMA as compared to ETT. [62] Besides, active upper respiratory tract infections are common in these children, and studies have shown that the incidence of respiratory complications is significantly lesser with LMA. [63],[64] Overall, it is important that both the surgeon and the anesthesiologist are familiar with its use, and the device is leak tested >15 cm H 2 O before surgery. [65] The different devices with flexible airway tubes (mentioned earlier in the article) should be preferred for all head and neck procedures.


  Prone Position Top


Several case reports have described the successful use of SGA in the prone position in children. Dingeman et al. used an LMA (5-year-old, Arnold Chiari malformation for decompressive craniectomy; 2005) and Taxak and Gopinath (2.65 kg neonate for meningomylocele surgery; 2011) used an i-gel as a rescue device following sudden accidental extubation in prone position. [66],[67] However, the author feels that their elective use in the prone position may be just an act of worthless heroism.


  Difficult Airway Top


Pediatric SGAs have redefined difficult airway, urging us to consider "Can intubate, Can ventilate" in place of "Can't intubate, Can't ventilate" in several circumstances. Though Air Q and Ambu Aura i are designed and used as a conduit for endotracheal intubation [68],[69],[70],[71],[72] there are many case reports of successful use of other SGAs (cLMA, i-gel) as primary or rescue airway in difficult airway situations. [73],[74],[75],[76],[77],[78],[79],[80],[81],[82] Walker used LMA in 34 children with Cormack-Lehane grade 3-4 without a single failure. [83] They could get the full view of the glottis (Grade I FOB view) in 73% and partial view (Grade II) in the rest 27% of the cases. In a recent retrospective analysis of difficult airways over a 4-year period, Jagannathan et al. showed successful use of an SGA in 96% cases where it was electively used for primary management (109 out of a total of 459 cases with Cormack-Lehane grade 3-4). [84] However, in an accompanying editorial Asai clarified that it did not mean that SGA can be used for all difficult airways (not for children at risk for pulmonary aspiration, with collapsible airway disease, ventilation required at high pressure, restricted mouth opening). [85]

In a recent survey on the practice of pediatric SGA in the UK, 99% of the respondents considered SGA as an important airway tool in difficult airway management. [86] The majority (79%) preferred the classically shaped laryngeal masks in failed intubation scenarios.


  Neonatal and Pediatric Resuscitation Top


2010 International Consensus on cardiopulmonary resuscitation mentions the role of LMA (Classic) as an alternative to mask/ETT or as a primary airway in neonate >2 kg weight and >34 weeks gestation. [87],[88],[89] ProSeal LMA has also been reported for use in neonatal resuscitation. [90],[91]

During pediatric resuscitation, LMA has been recommended in case of unsuccessful bag-mask ventilation or when endotracheal intubation is not possible. [92] Considering the airway characteristics, the newer SGAs are also expected to function similar to their older counterparts for resuscitation in infants and children.


  Problems and Failure Top


By far, it is well agreed that ventilation can be adequately provided with a SGA to a child, but the biggest fear is the risk of pulmonary aspiration. Though SGAs are used in adequately fasted patients and may be avoided in those with known high risk of aspiration, there may be other factors that can increase the risk of regurgitation such as inadequate depth of anesthesia, gastric insufflation during positive pressure ventilation due to oropharyngeal leaks and pneumoperitoneum. Nonetheless, mild regurgitation is not commonly known to result in clinically significant pulmonary aspiration. With the more frequent use of 2 nd generation SGAs and routine aspiration of the stomach contents after its insertion, these incidents are now rarely reported in children.

Lingual edema with large LMA in an infant after prolonged use and retention of plastic cuff shield in the oropharynx of a 5-year-old child, 1-day after removal of size 2 Ambu AuraStraight are some of the SGA-related adverse incidents reported in the literature. [93],[94] Currently, there is no evidence supporting the use of SGA for prolonged duration in children, and more studies would be needed for further insight.

Recently, Mathis et al., the guardian of the "big data of pediatric anesthesia" reported an incidence of 0.86% for LMA (Classic/Unique) failure in 11,910 planned pediatric cases vis-a-vis 1.1% in adults as shown by Ramachandran et al. in 2012. [95],[96],[97] They revealed obstruction (48%) as the leading cause and also brought out some of the clinical correlations associated with these failures (ENT surgeries, non-outpatient admission status, prolonged surgical duration, airway abnormality and patient transport). Although this data monolith reveals a favorably low incidence of LMA failure, it is not "one ring to rule them all" but "small pieces loosely joined" that matter. In this case, a large number of controlled trials that aim to study the power of the individual factor associations need to be analyzed.

As far as the newer SGAs are concerned, the studies are adequately powered for efficacy but there is currently limited safety data for these devices. Further research on animal and cadaveric models, as well as simulator-based studies may bring in more insight into the safety aspects of the SGAs.


  Conclusion Top


It is not that the "old order changeth" but it is the multifarious disposition of the new that has opened more doors for the pediatric airway. Notwithstanding the availability and cost factors, the newly introduced devices offer greater usability. The evolving SGAs have dawned a new era announcing novel horizons in pediatric airway management.

 
  References Top

1.
White MC, Cook TM, Stoddart PA. A critique of elective pediatric supraglottic airway devices. Paediatr Anaesth 2009;19 Suppl 1:55-65.  Back to cited text no. 1
    
2.
Ramesh S, Jayanthi R. Supraglottic airway devices in children. Indian J Anaesth 2011;55:476-82.  Back to cited text no. 2
[PUBMED]  Medknow Journal  
3.
Hudgins PA, Siegel J, Jacobs I, Abramowsky CR. The normal pediatric larynx on CT and MR. AJNR Am J Neuroradiol 1997;18:239-45.  Back to cited text no. 3
    
4.
Miller DM, Youkhana I, Karunaratne WU, Pearce A. Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment. Anaesthesia 2001;56:1069-72.  Back to cited text no. 4
    
5.
Clery G, Brimacombe J, Stone T, Keller C, Curtis S. Routine cleaning and autoclaving does not remove protein deposits from reusable laryngeal mask devices. Anesth Analg 2003;97:1189-91.  Back to cited text no. 5
    
6.
Coetzee GJ. Eliminating protein from reusable laryngeal mask airways. A study comparing routinely cleaned masks with three alternative cleaning methods. Anaesthesia 2003;58:346-53.  Back to cited text no. 6
    
7.
Richards E, Brimacombe J, Laupau W, Keller C. Protein cross-contamination during batch cleaning and autoclaving of the ProSeal laryngeal mask airway. Anaesthesia 2006;61:431-3.  Back to cited text no. 7
    
8.
Brown P, Preece M, Brandel JP, Sato T, McShane L, Zerr I, et al. Iatrogenic Creutzfeldt-Jakob disease at the millennium. Neurology 2000;55:1075-81.  Back to cited text no. 8
    
9.
Association of Anaesthetists of Great Britain and Ireland. Infection Control in Anaesthesia. Available from: http://www.aagbi.org/sites/default/files/infection02.pdf. [Last accessed on 2014 Apr 20].  Back to cited text no. 9
    
10.
Schloss B, Rice J, Tobias JD. The laryngeal mask in infants and children: What is the cuff pressure? Int J Pediatr Otorhinolaryngol 2012;76:284-6.  Back to cited text no. 10
    
11.
Ouellette RG. The effect of nitrous oxide on laryngeal mask cuff pressure. AANA J 2000;68:411-4.  Back to cited text no. 11
    
12.
Hockings L, Heaney M, Chambers NA, Erb TO, von Ungern-Sternberg BS. Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation. Paediatr Anaesth 2010;20:313-7.  Back to cited text no. 12
    
13.
Ong M, Chambers NA, Hullet B, Erb TO, von Ungern-Sternberg BS. Laryngeal mask airway and tracheal tube cuff pressures in children: Are clinical endpoints valuable for guiding inflation? Anaesthesia 2008;63:738-44.  Back to cited text no. 13
    
14.
Licina A, Chambers NA, Hullett B, Erb TO, von Ungern-Sternberg BS. Lower cuff pressures improve the seal of pediatric laryngeal mask airways. Paediatr Anaesth 2008;18:952-6.  Back to cited text no. 14
    
15.
von Ungern-Sternberg BS, Erb TO, Chambers NA, Heaney M. Laryngeal mask airways: To inflate or to deflate after insertion? Paediatr Anaesth 2009;19:837-43.  Back to cited text no. 15
    
16.
Xue FS, Wang Q, Yuan J, Xiong J, Liao X. Is fibreoptic scoring a valuable means to assess proper positioning of the classic laryngeal mask airway in paediatric patients? Anaesth Intensive Care 2010;38:591-2.  Back to cited text no. 16
[PUBMED]    
17.
Loke GP, Tan SM, Ng AS. Appropriate size of laryngeal mask airway for children. Anaesth Intensive Care 2002;30:771-4.  Back to cited text no. 17
    
18.
Von Ungern-Sternberg BS, Wallace CJ, Sticks S, Erb TO, Chambers NA. Fibreoptic assessment of paediatric sized laryngeal mask airways. Anaesth Intensive Care 2010;38:50-4.  Back to cited text no. 18
    
19.
Lopez-Gil M, Brimacombe J, Garcia G. A randomized non-crossover study comparing the ProSeal and Classic laryngeal mask airway in anaesthetized children. Br J Anaesth 2005;95:827-30.  Back to cited text no. 19
    
20.
Shimbori H, Ono K, Miwa T, Morimura N, Noguchi M, Hiroki K. Comparison of the LMA-ProSeal and LMA-Classic in children. Br J Anaesth 2004;93:528-31.  Back to cited text no. 20
    
21.
Szmuk P, Ghelber O, Matuszczak M, Rabb MF, Ezri T, Sessler DI. A prospective, randomized comparison of cobra perilaryngeal airway and laryngeal mask airway unique in pediatric patients. Anesth Analg 2008;107:1523-30.  Back to cited text no. 21
    
22.
Gaitini L, Carmi N, Yanovski B, Tome R, Resnikov I, Gankin I, et al. Comparison of the CobraPLA (Cobra Perilaryngeal Airway) and the Laryngeal Mask Airway Unique in children under pressure controlled ventilation. Paediatr Anaesth 2008;18:313-9.  Back to cited text no. 22
    
23.
Polaner DM, Ahuja D, Zuk J, Pan Z. Video assessment of supraglottic airway orientation through the perilaryngeal airway in pediatric patients. Anesth Analg 2006;102:1685-8.  Back to cited text no. 23
    
24.
Passariello M, Almenrader N, Coccetti B, Haiberger R, Pietropaoli P. Insertion characteristics, sealing pressure and fiberoptic positioning of CobraPLA in children. Paediatr Anaesth 2007;17:977-82.  Back to cited text no. 24
    
25.
Sunder RA, Sinha R, Agarwal A, Perumal BC, Paneerselvam SR. Comparison of Cobra perilaryngeal airway (CobraPLA™) with flexible laryngeal mask airway in terms of device stability and ventilation characteristics in pediatric ophthalmic surgery. J Anaesthesiol Clin Pharmacol 2012;28:322-5.  Back to cited text no. 25
[PUBMED]  Medknow Journal  
26.
Goldmann K, Jakob C. Size 2 ProSeal laryngeal mask airway: A randomized, crossover investigation with the standard laryngeal mask airway in paediatric patients. Br J Anaesth 2005;94:385-9.  Back to cited text no. 26
    
27.
Goldmann K, Roettger C, Wulf H. The size 1(1/2) ProSeal laryngeal mask airway in infants: A randomized, crossover investigation with the Classic laryngeal mask airway. Anesth Analg 2006;102:405-10.  Back to cited text no. 27
    
28.
Jagannathan N, Sohn LE, Chang E, Sawardekar A. A cohort evaluation of the laryngeal mask airway-Supreme™ in children. Paediatr Anaesth 2012;22:759-64.  Back to cited text no. 28
    
29.
Jagannathan N, Sohn LE, Sawardekar A, Chang E, Langen KE, Anderson K. A randomised trial comparing the laryngeal mask airway Supreme™ with the laryngeal mask airway Unique™ in children. Anaesthesia 2012;67:139-44.  Back to cited text no. 29
    
30.
Jagannathan N, Sommers K, Sohn LE, Sawardekar A, Shah RD, Mukherji II, et al. A randomized equivalence trial comparing the i-gel and laryngeal mask airway Supreme in children. Paediatr Anaesth 2013;23:127-33.  Back to cited text no. 30
    
31.
Jagannathan N, Sohn L, Sommers K, Belvis D, Shah RD, Sawardekar A, et al. A randomized comparison of the laryngeal mask airway Supreme™ and laryngeal mask airway Unique™ in infants and children: Does cuff pressure influence leak pressure? Paediatr Anaesth 2013;23:927-33.  Back to cited text no. 31
    
32.
Hosten T, Gürkan Y, Kus A, Özdamar D, Aksu C, Solak M, et al. Comparison of ProSeal LMA with Supreme LMA in paediatric patients. Acta Anaesthesiol Scand 2013;57:996-1001.  Back to cited text no. 32
    
33.
Jagannathan N, Sohn LE, Sawardekar A, Gordon J, Langen KE, Anderson K. A randomised comparison of the LMA Supreme™ and LMAProSeal™ in children. Anaesthesia 2012;67:632-9.  Back to cited text no. 33
    
34.
Francksen H, Duetschke P, Renner J, Berthold B. A comparison of the i-gel with the LMA Supreme in nonparalysed anaesthetized children. Eur J Anaesthesiol 2012;29:231.  Back to cited text no. 34
    
35.
Schalk R, Scheller B, Peter N, Rosskopf W, Byhahn C, Zacharowski K, et al. Laryngeal tube II: Alternative airway for children?. Anaesthesist 2011;60:525-33.  Back to cited text no. 35
    
36.
Richebé P, Semjen F, Cros AM, Maurette P. Clinical assessment of the laryngeal tube in pediatric anesthesia. Paediatr Anaesth 2005;15:391-6.  Back to cited text no. 36
    
37.
Gaitini L, Yanovski B, Toame R, Carmi N, Somri M. Laryngeal tube suction II versus the ProSeal laryngeal mask in anesthetized children with spontaneous ventilation: 19AP6-3. Eur J Anaesthesiol 2007;24:203.  Back to cited text no. 37
    
38.
Whyte SD, Cooke E, Malherbe S. Usability and performance characteristics of the pediatric air-Q® intubating laryngeal airway. Can J Anaesth 2013;60:557-63.  Back to cited text no. 38
    
39.
Jagannathan N, Kho MF, Kozlowski RJ, Sohn LE, Siddiqui A, Wong DT. Retrospective audit of the air-Q intubating laryngeal airway as a conduit for tracheal intubation in pediatric patients with a difficult airway. Paediatr Anaesth 2011;21:422-7.  Back to cited text no. 39
    
40.
Jagannathan N, Sohn LE, Sawardekar A, Shah R, Ryan K, Jagannathan R, et al. A randomised comparison of the self-pressurised air-QTM intubating laryngeal airway with the LMA Unique™ in children. Anaesthesia 2012;67:973-9.  Back to cited text no. 40
    
41.
Theiler LG, Kleine-Brueggeney M, Luepold B, Stucki F, Seiler S, Urwyler N, et al. Performance of the pediatric-sized i-gel compared with the Ambu AuraOnce laryngeal mask in anesthetized and ventilated children. Anesthesiology 2011;115:102-10.  Back to cited text no. 41
    
42.
Jagannathan N, Sohn LE, Sawardekar A, Gordon J, Shah RD, Mukherji II, et al. A randomized trial comparing the Ambu® Aura-i™ with the air-Q™ intubating laryngeal airway as conduits for tracheal intubation in children. Paediatr Anaesth 2012;22:1197-204.  Back to cited text no. 42
    
43.
Goyal R, Shukla RN, Kumar G. Comparison of size 2 i-gel supraglottic airway with LMA-ProSeal™ and LMA-Classic™ in spontaneously breathing children undergoing elective surgery. Paediatr Anaesth 2012;22:355-9.  Back to cited text no. 43
    
44.
Fukuhara A, Okutani R, Oda Y. A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: Performance and fiberoptic findings. J Anesth 2013;27:1-6.  Back to cited text no. 44
    
45.
Mitra S, Das B, Jamil SN. Comparison of Size 2.5 i-gel™ with ProSeal LMA™ in anaesthetised, paralyzed children undergoing elective surgery. N Am J Med Sci 2012;4:453-7.  Back to cited text no. 45
    
46.
Ozdamar D, Güvenç BH, Toker K, Solak M, Ekingen G. Comparison of the effect of LMA and ETT on ventilation and intragastric pressure in pediatric laparoscopic procedures. Minerva Anestesiol 2010;76:592-9.  Back to cited text no. 46
    
47.
Greif R, Theiler L. The use of supraglottic airway devices in pediatric laparoscopic surgery. Minerva Anestesiol 2010;76:575-6.  Back to cited text no. 47
[PUBMED]    
48.
Sinha A, Sharma B, Sood J. ProSeal as an alternative to endotracheal intubation in pediatric laparoscopy. Paediatr Anaesth 2007;17:327-32.  Back to cited text no. 48
    
49.
Mironov PI, Estekhin AM, Mirasov AA. Anaesthetic maintenance with laryngeal mask for a laparoscopic surgery in pediatric patients. Anesteziol Reanimatol 2013;1:10-4.  Back to cited text no. 49
[PUBMED]    
50.
Fuentes-García VE, Morales-Pérez E, Ramírez-Mora JC, Alarcòn-Almanza JM, Moyao-García D, Blanco-Rodríguez G, et al. A randomized trial comparing laryngeal mask airway to endotracheal tube in children undergoing upper gastrointestinal endoscopy. Acta Biomed 2006;77:90-4.  Back to cited text no. 50
    
51.
Lopez-Gil M, Brimacombe J, Díaz-Regañon G. Anesthesia for pediatric gastroscopy: A study comparing the ProSeal laryngeal mask airway with nasal cannulae. Paediatr Anaesth 2006;16:1032-5.  Back to cited text no. 51
    
52.
Naguib ML, Streetman DS, Clifton S, Nasr SZ. Use of laryngeal mask airway in flexible bronchoscopy in infants and children. Pediatr Pulmonol 2005;39:56-63.  Back to cited text no. 52
    
53.
Baker PA, Brunette KE, Byrnes CA, Thompson JM. A prospective randomized trial comparing supraglottic airways for flexible bronchoscopy in children. Paediatr Anaesth 2010;20:831-8.  Back to cited text no. 53
    
54.
Schieble T, Patel A, Davidson M. Laryngeal mask airway (LMA) artefact resulting in MRI misdiagnosis. Pediatr Radiol 2008;38:328-30.  Back to cited text no. 54
    
55.
Taxak S, Bhardwaj M, Gopinath A. The i-gel(™): A promising airway device for magnetic resonance imaging suite. J Anaesthesiol Clin Pharmacol 2012;28:263-4.  Back to cited text no. 55
[PUBMED]  Medknow Journal  
56.
Zaballos M, Bastida E, del Castillo T, de Villoria JG, Jiménez C. In vitro study of magnetic resonance imaging artefacts of six supraglottic airway devices. Anaesthesia 2010;65:569-72.  Back to cited text no. 56
    
57.
Grebenik CR, Ferguson C, White A. The laryngeal mask airway in pediatric radiotherapy. Anesthesiology 1990;72:474-7.  Back to cited text no. 57
    
58.
Trevisanuto D, Verghese C, Doglioni N, Ferrarese P, Zanardo V. Laryngeal mask airway for the interhospital transport of neonates. Pediatrics 2005;115:e109-11.  Back to cited text no. 58
    
59.
Clarke MB, Forster P, Cook TM. Airway management for tonsillectomy: A national survey of UK practice. Br J Anaesth 2007;99:425-8.  Back to cited text no. 59
    
60.
Peng A, Dodson KM, Thacker LR, Kierce J, Shapiro J, Baldassari CM. Use of laryngeal mask airway in pediatric adenotonsillectomy. Arch Otolaryngol Head Neck Surg 2011;137:42-6.  Back to cited text no. 60
    
61.
John RE, Hill S, Hughes TJ. Airway protection by the laryngeal mask. A barrier to dye placed in the pharynx. Anaesthesia 1991;46:366-7.  Back to cited text no. 61
    
62.
Sierpina DI, Chaudhary H, Walner DL, Villines D, Schneider K, Lowenthal M, et al. Laryngeal mask airway versus endotracheal tube in pediatric adenotonsillectomy. Laryngoscope 2012;122:429-35.  Back to cited text no. 62
    
63.
Tait AR, Pandit UA, Voepel-Lewis T, Munro HM, Malviya S. Use of the laryngeal mask airway in children with upper respiratory tract infections: A comparison with endotracheal intubation. Anesth Analg 1998;86:706-11.  Back to cited text no. 63
    
64.
Huang HJ, Fang XM. Effect of endotracheal intubation and laryngeal mask airway on perioperative respiratory adverse events in children with upper airway infections. Zhonghua Yi Xue Za Zhi 2013;93:3626-8.  Back to cited text no. 64
    
65.
Turnbull J, Patel A. The use of the laryngeal mask airway in ENT surgery: Facts and fiction. Trends Anaesth Crit Care 2013;3:346-50.  Back to cited text no. 65
    
66.
Dingeman RS, Goumnerova LC, Goobie SM. The use of a laryngeal mask airway for emergent airway management in a prone child. Anesth Analg 2005;100:670-1.  Back to cited text no. 66
    
67.
Taxak S, Gopinath A. Insertion of the i-gel airway in prone position. Minerva Anestesiol 2010;76:381.  Back to cited text no. 67
[PUBMED]    
68.
Jagannathan N, Roth AG, Sohn LE, Pak TY, Amin S, Suresh S. The new air-Q intubating laryngeal airway for tracheal intubation in children with anticipated difficult airway: A case series. Paediatr Anaesth 2009;19:618-22.  Back to cited text no. 68
    
69.
Jagannathan N, Wong DT. Successful tracheal intubation through an intubating laryngeal airway in pediatric patients with airway hemorrhage. J Emerg Med 2011;41:369-73.  Back to cited text no. 69
    
70.
Sinha R, Chandralekha, Ray BR. Evaluation of air-Q™ intubating laryngeal airway as a conduit for tracheal intubation in infants - a pilot study. Paediatr Anaesth 2012;22:156-60.  Back to cited text no. 70
    
71.
Khanna P, Baidya DK, Tomar V, Agarwal A. Successful use of air-Q intubating laryngeal airway after failed rapid sequence intubation in a child with Rubinstein-Taybi syndrome. Indian J Anaesth 2013;57:203-4.  Back to cited text no. 71
[PUBMED]  Medknow Journal  
72.
Khan TH, Ghayas A, Ayesha, Khushbakht S, Ahmed A, Khan N. Successful intubation with air-Q in Pierre Robin syndrome. Anaesth Pain Intensive Care 2013;17:71-74.  Back to cited text no. 72
    
73.
Ebata T, Nishiki S, Masuda A, Amaha K. Anaesthesia for Treacher Collins syndrome using a laryngeal mask airway. Can J Anaesth 1991;38:1043-5.  Back to cited text no. 73
    
74.
Johnson CM, Sims C. Awake fibreoptic intubation via a laryngeal mask in an infant with Goldenhar's syndrome. Anaesth Intensive Care 1994;22:194-7.  Back to cited text no. 74
    
75.
Bucx MJ, Grolman W, Kruisinga FH, Lindeboom JA, Van Kempen AA. The prolonged use of the laryngeal mask airway in a neonate with airway obstruction and Treacher Collins syndrome. Paediatr Anaesth 2003;13:530-3.  Back to cited text no. 75
    
76.
Takita K, Kobayashi S, Kozu M, Morimoto Y, Kemmotsu O. Successes and failures with the laryngeal mask airway (LMA) in patients with Treacher Collins syndrome: A case series. Can J Anaesth 2003;50:969-70.  Back to cited text no. 76
    
77.
Leal-Pavey YR. Use of the LMA classic to secure the airway of a premature neonate with Smith-Lemli-Opitz syndrome: A case report. AANA J 2004;72:427-30.  Back to cited text no. 77
    
78.
Cain JM, Mason LJ, Martin RD. Airway management in two of newborns with Pierre Robin Sequence: The use of disposable vs multiple use LMA for fiberoptic intubation. Paediatr Anaesth 2006;16:1274-6.  Back to cited text no. 78
    
79.
Asai T, Nagata A, Shingu K. Awake tracheal intubation through the laryngeal mask in neonates with upper airway obstruction. Paediatr Anaesth 2008;18:77-80.  Back to cited text no. 79
    
80.
Scheller B, Schalk R, Byhahn C, Peter N, L'Allemand N, Kessler P, et al. Laryngeal tube suction II for difficult airway management in neonates and small infants. Resuscitation 2009;80:805-10.  Back to cited text no. 80
    
81.
Kim YL, Seo DM, Shim KS, Kim EJ, Lee JH, Lee SG, et al. Successful tracheal intubation using fiberoptic bronchoscope via an I-gel™ supraglottic airway in a pediatric patient with Goldenhar syndrome: A case report. Korean J Anesthesiol 2013;65:61-5.  Back to cited text no. 81
    
82.
Hosking J, Zoanetti D, Carlyle A, Anderson P, Costi D. Anesthesia for Treacher Collins syndrome: A review of airway management in 240 pediatric cases. Paediatr Anaesth 2012;22:752-8.  Back to cited text no. 82
    
83.
Walker RW. The laryngeal mask airway in the difficult paediatric airway: An assessment of positioning and use in fibreoptic intubation. Paediatr Anaesth 2000;10:53-8.  Back to cited text no. 83
    
84.
Jagannathan N, Sequera-Ramos L, Sohn L, Wallis B, Shertzer A, Schaldenbrand K. Elective use of supraglottic airway devices for primary airway management in children with difficult airways. Br J Anaesth 2014;112:742-8.  Back to cited text no. 84
    
85.
Asai T. Is it safe to use supraglottic airway in children with difficult airways? Br J Anaesth 2014;112:620-2.  Back to cited text no. 85
    
86.
Bradley AE, White MC, Engelhardt T, Bayley G, Beringer RM. Current UK practice of pediatric supraglottic airway devices - A survey of members of the Association of Paediatric Anaesthetists of Great Britain and Ireland. Paediatr Anaesth 2013;23:1006-9.  Back to cited text no. 86
    
87.
Perlman JM, Wyllie J, Kattwinkel J, Atkins DL, Chameides L, Goldsmith JP, et al. Neonatal resuscitation: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Pediatrics 2010;126:e1319-44.  Back to cited text no. 87
[PUBMED]    
88.
Zhu XY, Lin BC, Zhang QS, Ye HM, Yu RJ. A prospective evaluation of the efficacy of the laryngeal mask airway during neonatal resuscitation. Resuscitation 2011;82:1405-9.  Back to cited text no. 88
    
89.
Grein AJ, Weiner GM. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation. Cochrane Database Syst Rev 2005;18:2. CD003314.  Back to cited text no. 89
    
90.
Micaglio M, Doglioni N, Parotto M, Zanardo V, Ori C, Trevisanuto D. Training for neonatal resuscitation with the laryngeal mask airway: A comparison of the LMA-ProSeal and the LMA-Classic in an airway management manikin. Paediatr Anaesth 2006;16:1028-31.  Back to cited text no. 90
    
91.
Micaglio M, Ori C, Parotto M, Zanardo V, Trevisanuto D. The ProSeal laryngeal mask airway for neonatal resuscitation: First reports. Paediatr Anaesth 2007;17:499.  Back to cited text no. 91
[PUBMED]    
92.
Kleinman ME, Chameides L, Schexnayder SM, Samson RA, Hazinski MF, Atkins DL, et al. Part 14: Pediatric advanced life support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation 2010;122:S876-908.  Back to cited text no. 92
[PUBMED]    
93.
Stillman P. Lingual oedema associated with prolonged use of an inappropriately large laryngeal mask airway in an infant. Paediatr Anaesth 2003;13:637-9.  Back to cited text no. 93
    
94.
Baron-Shahaf D, Weissman A, Katz YS. A Call of Alert for the Ambu AuraStraight Disposable Laryngeal Mask. A A Case Rep 2014;2:51-2.  Back to cited text no. 94
    
95.
Mathis MR, Haydar B, Taylor EL, Morris M, Malviya SV, Christensen RE, et al. Failure of the Laryngeal Mask Airway Unique™ and Classic™ in the pediatric surgical patient: A study of clinical predictors and outcomes. Anesthesiology 2013;119:1284-95.  Back to cited text no. 95
    
96.
Litman RS. Complications of laryngeal masks in children: Big data comes to pediatric anesthesia. Anesthesiology 2013;119:1239-40.  Back to cited text no. 96
    
97.
Ramachandran SK, Mathis MR, Tremper KK, Shanks AM, Kheterpal S. Predictors and clinical outcomes from failed Laryngeal Mask Airway Unique™: A study of 15,795 patients. Anesthesiology 2012;116:1217-26.  Back to cited text no. 97
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6]
 
 
    Tables

  [Table 1]


This article has been cited by
1 Comparison of leakage test and ultrasound imaging to validate ProSeal supraglottic airway device placement
SachinE Ajithan,Archana Puri,MukulC Kapoor
Journal of Anaesthesiology Clinical Pharmacology. 2020; 36(2): 227
[Pubmed] | [DOI]
2 Neonatal resuscitation using a supraglottic airway device for improved mortality and morbidity outcomes in a low-income country: study protocol for a randomized trial
Nicolas J. Pejovic,Susanna Myrnerts Höök,Josaphat Byamugisha,Tobias Alfvén,Clare Lubulwa,Francesco Cavallin,Jolly Nankunda,Hege Ersdal,Giulia Segafredo,Mats Blennow,Daniele Trevisanuto,Thorkild Tylleskär
Trials. 2019; 20(1)
[Pubmed] | [DOI]
3 Laryngeal Mask Airway Versus Other Airway Devices for Anesthesia in Children With an Upper Respiratory Tract Infection
Ana Lygia R. de Carvalho,Roberto B. Vital,Carlos C. S. de Lira,Igor B. Magro,Patrícia T. S. Sato,Laís H. N. Lima,Leandro G. Braz,Norma S. P. Módolo
Anesthesia & Analgesia. 2018; 127(4): 941
[Pubmed] | [DOI]
4 A comparison of i-gel™ and Laryngeal Mask Airway Supreme™ during general anesthesia in infants
Yoon Chan Lee,Kyoung Seop Yoon,Sang Yoong Park,So Ron Choi,Chan Jong Chung
Korean Journal of Anesthesiology. 2018; 71(1): 37
[Pubmed] | [DOI]
5 Basic airway equipments in pediatric cardiac arrest management
Kemal Tolga Saracoglu,Ayten Saracoglu,Haluk Kafali
Trends in Anaesthesia and Critical Care. 2016;
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
   Abstract
  Introduction
   Evolution of Sup...
  The Anatomy
   General Consider...
  Cuff Pressure
   Oro-pharyngeal S...
   Fiberoptic View ...
  The Cost Factor
   Overview of Supr...
   Air Q Masked Lar...
  Ambu Aura
  Specific Scenarios
   Gastrointestinal...
   Fiberoptic Bronc...
  Remote Locations
  Adenotonsillectomy
  Prone Position
  Difficult Airway
   Neonatal and Ped...
  Problems and Failure
  Conclusion
   References
   Article Figures
   Article Tables

 Article Access Statistics
    Viewed4446    
    Printed53    
    Emailed0    
    PDF Downloaded2030    
    Comments [Add]    
    Cited by others 5    

Recommend this journal