ORIGINAL ARTICLE
Year : 2016  |  Volume : 32  |  Issue : 1  |  Page : 74-79

Validation of simple and inexpensive algometry using sphygmomanometer cuff and neuromuscular junction monitor with standardized laboratory algometer


1 Department of Anesthesiology and Intensive Care, Nizam's Institute of Medical Sciences, Hyderabad, Andhra Pradesh, India
2 Department of Clinical Pharmacology and Medical Research, Nizam's Institute of Medical Sciences, Hyderabad, Andhra Pradesh, India

Correspondence Address:
Dr. Padmaja Durga
Department of Anesthesiology and Intensive Care, Nizam's Institute of Medical Sciences, Hyderabad, Andhra Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-9185.173390

Rights and Permissions

Background and Aims: The availability, ergonomics and economics prohibit the routine use of algometers in clinical practice and research by the anesthesiologists. A simple bedside technique of quantitative pain measurement would enable the routine use of algometry. We proposed to validate simple pain provocation using sphygmomanometer cuff and the electric stimulation of neuromuscular junction monitor (TOF-guard, Organon Teknika) to measure pain against a standardized laboratory pressure algometer. Material and Methods: Pain detection threshold (Pdt) and pain tolerance threshold (Ptt) were measured in forty healthy volunteers of both genders, using the above three techniques. All measurements were repeated three times. The co-efficient of inter-rater reliability (or consistency) between three independent measurements obtained from each of the techniques was determined by Cronbach's co-efficient alpha (α C). The correlation between the mean Pdt and Ptt values recorded by standardized algometer and the sphygmomanometer technique and nerve stimulator technique was performed using Pearson Correlation. An r >0.5 and a two-tailed significance of <0.05 were considered as good correlation between the standardized algometer and the tested techniques. Results: There was a good inter-rater reliability (α C > 0.7) for the three techniques. There was a good correlation with r >0.65 (P < 0.001) between the measurements of standardized pressure algometer and the two techniques being tested as alternatives for algometer to measure pain. Conclusion: The sphygmomanometer cuff technique and electrical stimulation with the peripheral nerve stimulator to measure pain threshold and tolerance provide a simple, efficient, repeatable measure of pain intensity and can be used as suitable alternatives to standard algometers.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1363    
    Printed38    
    Emailed0    
    PDF Downloaded280    
    Comments [Add]    

Recommend this journal