Users Online: 1093 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions | Subscribe | Contacts | Login 
 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 34  |  Issue : 4  |  Page : 490-495

Assessment of awake i-gel™ insertion for fiberoptic-guided intubation in patients with predicted difficult airway: A prospective, observational study


Department of Anesthesiology, University Hospital Fundacion Jimenez Diaz, Madrid, Spain

Correspondence Address:
Julian Arevalo Ludena
Department of Anesthesiology, University Hospital Fundacion Jimenez Diaz, Avenida Reyes Catolicos, 2. C. P: 28040, Madrid
Spain
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joacp.JOACP_329_15

Rights and Permissions

Background and Aims: Orotracheal intubation (OTI) with fiberoptic bronchoscope (FOB) in spontaneous ventilation is one of the main techniques for patients with predicted difficult airway. Latest generation supraglottic airway devices have been designed to allow OTI through them. We assessed the safety and effectiveness of FOB-guided OTI through i-gel™ device which was inserted in spontaneously breathing patients with predicted difficult airway. Material and Methods: Eighty-five patients with difficult airway predictors were included. The i-gel was inserted under oropharyngeal local anaesthesia and sedation. After checking the adequate ventilation through the i-gel with capnography curve, general anaesthesia was induced in order to introduce the endotracheal tube guided by FOB. We recorded the i-gel insertion time (tgel), intubation time (tint), O2 saturation in pulse oximetry (SpO2) at different times: basal (t0), after 3 min of preoxygenation with a face mask at 100% FiO2 (t1), after i-gel mask insertion (t2) and after intubation (t3). Adverse events during the procedure were also recorded. Results: All patients were successfully intubated. SpO2 values were: 96.9 ± 1.2 (t0), 99.0 ± 0.9 (t1), 96.2 ± 2.4 (t2), 96.0 ± 2.5 (t3). tgel and tint were 38.0 ± 7.8 s and 36.5 ± 5.6 s, respectively. No serious adverse events were recorded and no patient suffered airway trauma. Conclusion: I-gel insertion in spontaneous ventilation secures the airway before achieving fiberoptic intubation without the occurrence of adverse events. More studies might be necessary in order to confirm the results presented, but we consider that the technique described is a safe and effective alternative to classic OTI with FOB in spontaneously breathing patients with predicted difficult airway.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed353    
    Printed5    
    Emailed0    
    PDF Downloaded100    
    Comments [Add]    

Recommend this journal