ORIGINAL ARTICLE
Year : 2019  |  Volume : 35  |  Issue : 1  |  Page : 30-35

Comparative evaluation of I-gel vs. endotracheal intubation for adequacy of ventilation in pediatric patients undergoing laparoscopic surgeries


1 Department of Anaesthesiology, Maulana Azad Medical College, New Delhi, India
2 Department of Paediatric Surgery, Maulana Azad Medical College, New Delhi, India

Correspondence Address:
Megha Kohli
Department of Anaesthesiology, Maulana Azad Medical College, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joacp.JOACP_249_17

Rights and Permissions

Background and Aims: The use of newer supraglottic devices has been extended to laparoscopic procedures. We conducted this study to compare and evaluate the efficacy of these two devices in pediatric laparoscopic surgeries. Material and Methods: Eighty children, 2–8 years of age, scheduled for elective short laparoscopic procedures were randomly allocated to the I-gel or endotracheal tube (ETT) group. Standard anesthesia protocol was followed for inhalational induction. I-gel or ETT was inserted according to the manufacturer's recommendations. Ventilation was set with tidal volume 10 ml/kg and a respiratory rate of 16/min. Carboperitoneum was achieved up to an intra-abdominal pressure of 12 mmHg. Statistical Analysis: The primary outcome variable was adequacy of ventilation (peak airway pressure, end-tidal CO2, minute ventilation, and SPO2). These variables were recorded after securing airway, after carboperitoneum and desufflation of the peritoneal cavity. The oropharyngeal leak pressures were also noted. Statistical analysis was done using SPSS software version 17.0. P <0.05 was considered statistically significant. Results: No significant difference was observed in the heart rate or mean arterial pressure. There was a significant increase in the PECO2and peak airway pressure after creation of carboperitoneum. There was significant increase in minute ventilation in both groups after creation of carboperitoneum. Conclusion: To conclude, I-gel is comparable to endotracheal intubation in terms of adequacy of ventilation. The increase in peak airway pressures is less with I-gel. In addition, postoperative complications are fewer with I-gel.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed311    
    Printed10    
    Emailed0    
    PDF Downloaded87    
    Comments [Add]    

Recommend this journal