Users Online: 592 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions | Subscribe | Contacts | Login 


RSACP wishes to inform that it shall be discontinuing the dispatch of print copy of JOACP to it's Life members. The print copy of JOACP will be posted only to those life members who send us a written confirmation for continuation of print copy.
Kindly email your affirmation for print copies to dranjugrewal@gmail.com preferably by 30th June 2019.

 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 35  |  Issue : 4  |  Page : 540-545

The supraglottic airway device as first line of management in anticipated difficult mask ventilation in the morbidly obese


Max Institute of Minimal Access, Metabolic and Bariatric Surgery, Max Hospital, Saket, New Delhi, India

Correspondence Address:
Dr. Aparna Sinha
210 Sukhdev Vihar, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joacp.JOACP_159_19

Rights and Permissions

Background and Aims: Supraglottic airway devices (SGAs) are used to rescue difficult and failed mask ventilation (DMV). We aimed to use the SGA as first-line device, prior to obtaining a definitive airway and to find any predictors of difficulty for the same, in the morbidly obese patients. Material and Methods: Obese surgical patients [body mass index (BMI) >35 kg/m2] were investigated. Difficulties with bag mask ventilation (MV) was graded using the following scale: MV-1, one anesthesiologist unassisted could achieve MV and maintain SpO2 >90%; MV-2, one additional anesthesiologist was needed to facilitate MV to achieve SpO2> 90%; MV-3, two additional anesthesiologists were needed for this purpose; and MV-3P, when a supraglottic device was required to ventilate and maintain SpO2more than 90%. Parameters studied were age, gender, neck circumference (NC), BMI, STOPBANG score, and safe apnea time (SAT). Results: Logistic regression was performed for predictors of MV-3P; receiver operating characteristic curve was used to locate the best cut-off. Analysis of 834 morbidly obese patients revealed an incidence of MV 1/2/3/3-P as 16%/38%/27%/19%, respectively. DMV was associated with BMI ≥50 kg/m2, NC ≥49.5 cm, and STOPBANG ≥6; P < 0.001. The mean SAT for a population with mean BMI 48 ± 8 kg/m2 was 256 ± 66 s. The SAT showed inverse relation to BMI and NC. As per our results, the NC was the single most important predictor of MV-3P, with sensitivity 0.62 and specificity 0.85 at best cut-off 49.5 cm; P < 0.001. Conclusion: NC ≥49.5 cm is strongly associated with low SAT and need for SGA to achieve MV. SGA may provide safety for initial management following induction of anesthesia in this patient population.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed216    
    Printed0    
    Emailed0    
    PDF Downloaded45    
    Comments [Add]    

Recommend this journal