The influence of initial target effect-site concentrations of propofol on the similarity of effect-sites concentrations at loss and return of consciousness in elderly female patients with the Diprifusor system


Satoshi Shibuta1, Seitetsu Kanemura2, Osamu Uchida1, Takashi Mashimo1 
1 Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine D7, Osaka University, Yamadaoka, Suita, Japan
2 Department of Anesthesia, Gratia Hospital, Awaomadaninishi, Mino, Japan

Correspondence Address:
Satoshi Shibuta
Department of Anesthesiology and Intensive Care Medicine, Graduate School of Medicine D7, Osaka University, 2-2, Yamadaoka, Suita-city, Osaka 565-0871
Japan

Background : Whether effect-site concentrations of propofol (Cep) at loss of consciousness and return of consciousness (LOC and ROC, respectively) in elderly women using Diprifusor are similar is unclear. We investigated whether differences in initial target Cep (Ctarget) alter similarities between Cep values at LOC and ROC. Materials and Methods: In this study, female patients (n = 58, age = 72.5 ± 1.1 years) undergoing knee arthroplasty were administered propofol with Diprifusor. Cep at LOC and ROC were estimated for different Ctarget values (3.0-4.5 mg/ml). Pearson«SQ»s correlation coefficient analysis and simple regression were performed to assess the relationship between Cep at LOC and ROC for each Ctarget. Differences in correlation coefficients of regression lines obtained from each Ctarget group were determined using the t-test. Results: The different Ctarget groups did not show significant differences in total propofol levels and in Cep values at LOC or ROC. However, Cep at ROC was significantly higher than Cep at LOC when Ctarget was 4.0 and 4.5 μg/ml, whereas these Cep values were not significantly different in low Ctarget groups. Strong positive correlations were observed between Cep at LOC and ROC for all Ctarget groups. Regression coefficients for the different Ctarget groups were not significantly different. Compared to low (≤3.5 μg/ml) Ctarget groups, high Ctarget groups showed significantly shorter time until LOC. Induction quality was not significantly different among the groups. Conclusions: In elderly women, Cep values at LOC are strong predictors of Cep at ROC when Ctarget is 3.0-4.5 μg/ml. High Ctarget groups (≥4.0 μg/ml) exhibited shorter induction times with normal cardiovascular stability.


How to cite this article:
Shibuta S, Kanemura S, Uchida O, Mashimo T. The influence of initial target effect-site concentrations of propofol on the similarity of effect-sites concentrations at loss and return of consciousness in elderly female patients with the Diprifusor system.J Anaesthesiol Clin Pharmacol 2012;28:194-199


How to cite this URL:
Shibuta S, Kanemura S, Uchida O, Mashimo T. The influence of initial target effect-site concentrations of propofol on the similarity of effect-sites concentrations at loss and return of consciousness in elderly female patients with the Diprifusor system. J Anaesthesiol Clin Pharmacol [serial online] 2012 [cited 2020 Aug 4 ];28:194-199
Available from: http://www.joacp.org/article.asp?issn=0970-9185;year=2012;volume=28;issue=2;spage=194;epage=199;aulast=Shibuta;type=0