Journal of Anaesthesiology Clinical Pharmacology

ORIGINAL ARTICLE
Year
: 2016  |  Volume : 32  |  Issue : 4  |  Page : 515--518

Comparison of intubating laryngeal mask airway and fiberoptic bronchoscopy for endotracheal intubation in patients undergoing cervical discectomy


Kolli S Chalam, Jyothi Gupta 
 Department of Anaesthesiology, Sri Sathya Sai Institute of Higher Medical Sciences, Whitefield, Bengaluru, Karnataka, India

Correspondence Address:
Kolli S Chalam
Department of Anaesthesiology and Critical Care Medicine, Sri Sathya Sai Institute of Higher Medical Sciences, Whitefield, EPIP Area, Bangalore - 560 066, Karnataka
India

Background and Aims: Direct laryngoscopy is hazardous in patients with cervical posterior intervertebral disc prolapse (PIVD) as it may worsen the existing cord compression. To achieve smooth intubation, many adjuncts such as fiberoptic bronchoscope (FOB), video laryngoscopes, lighted stylets, and intubating laryngeal mask airways (ILMAs) are available. However, there is a paucity of literature comparing ILMA with fiberoptic intubation in patients with PIVD. Hence, this study was designed to compare the effectiveness of ILMA technique with FOB to accomplish endotracheal intubation in patients undergoing cervical discectomy. Material and Methods: Sixty patients of age group 20-60 years, of American Society of Anesthesiologists status I or II, were enrolled in this prospective and randomized study. They were allocated to one of the two groups, ILMA group and FOB group. The patients were intubated orally using either equipment, after dexmedetomidine premedication and induction of general anesthesia. Chi-square and Fisher exact tests were used to find the significance of study parameters on a categorical scale. Paired samples t-test and Student's t-test were used to find the significance of study parameters on a continuous scale. Significance was assessed at 5% level of significance. Results: Bronchoscopy was a faster method of securing airway as compared with ILMA (38.13 ± 11.52 vs. 29.83 ± 13.75 s). Tracheal intubation was successful in all 60 patients (100%), belonging to both groups. Conclusion: ILMA and FOB were comparable with regards to ease of intubation in terms of time, the number of attempts and hemodynamic stability.


How to cite this article:
Chalam KS, Gupta J. Comparison of intubating laryngeal mask airway and fiberoptic bronchoscopy for endotracheal intubation in patients undergoing cervical discectomy.J Anaesthesiol Clin Pharmacol 2016;32:515-518


How to cite this URL:
Chalam KS, Gupta J. Comparison of intubating laryngeal mask airway and fiberoptic bronchoscopy for endotracheal intubation in patients undergoing cervical discectomy. J Anaesthesiol Clin Pharmacol [serial online] 2016 [cited 2019 Dec 15 ];32:515-518
Available from: http://www.joacp.org/article.asp?issn=0970-9185;year=2016;volume=32;issue=4;spage=515;epage=518;aulast=Chalam;type=0